لاصق متخصص قائم على مذيبات مكلورة، للصق عزل قنوات الهواء، بما فيه الألياف الزجاجية والفلين والبولي يوريثان.

Product description

Getex N.F. is a high quality chlorinated solvent based specialty adhesive designed to bond duct insulation material.

Special features

☐ Resistant to humidity. ☐ Withstands high wind speeds. ☐ Provides excellent bond strengths with insulation material. ☐ Non-Flammable when wet.

Where to use

Due A/C Ducts to be insulated with e.g. Fiberglass, cork, polyurethane…etc.

Product data

Colour : Amber.

Application details

Brush, trowel, roller. Consistency : Liquid. Odour : Organic solvent Odour. Solvent type : Non-flammable chlorinated solvent. Coverage : 4 M²/kg Approx. APPLICATION OF ADHESIVE/ASSEMBLY ☐ Apply a thin layer of adhesive by brush or trowel. When touch dry the coated surfaces can be positioned and pressed together. ☐ Use solvents for cleaning brushes and equipment.

Application conditions

At a temperature ranging 5°C (41°F) to 40°C (104 °F). Relative humidity is below 75%.

Storage and handling

Product must be stored as per local regulations and should be kept in dry well ventilated location far from heat and direct sunlight. Can should be tightly closed after use. Mix well before use. Storage temperature range between 5°C (41°F) to 40°C (104 °F).

Storage and handling

SAFETY AND ENVIRONMENT ☐ Ventilate working area well. ☐ Personal protective materials such as special solvents masks, gloves and goggles should be used. ☐ Materials leftovers should be discarded in the proper way as per prevailing environmental regulations. ☐ Keep container closed when not in use to prevent solvent evaporation.

Standards and approvals

Supportive information is available upon request. Please consult with GTC Technical Service Dept.

Safety precautions

The following notes should be considered when using/applying material:- (a) Take precautions to prevent material entering the eyes (goggles should be worn, irrigate the eyes with water when become contaminated and obtain medical care at one). (b) Take precautions to avoid skin contact (gloves should be worn, barrier cream should be used). (c) Ensure that repeated contact of paint with skin is avoided. (d) Provide adequate ventilation. (Face masks must be worn). (e) Keep away from sparks and open flames (for solvent-based materials).

Pack sizes

☐ 4 kg Gallon