A specially developed two-pack & Heavy Duty Recoatable Polyurethane Coating based on Polyol/Polyisocyanate Resin designed to meet requirements of distinctively characterized cosmetic appearance, yet associated with an alternative selection of a Semi-Gloss Finish Version.
Special features
- A tough and abrasion resistant coat. - Excellent adhesion to a very wide range of substrates / surfaces. - Outstanding colour retention properties. - Excellent durability and weathering resistance. - Provides an appealing, cosmetic and non-yellowing finish. - Easily recoatable after extended periods of time. (No overcoating restrictions).
Where to use
As an Interior/Exterior decorative and protective coat offering an extremely hard/flexible film over concrete, steel, aluminium, tinned copper, galvanized steel, zinc coated steel, stone, bricks, asbestos, wood, marble, gypsum boards, fiberglass, PVC & UPVC Pipes ... etc, i.e. - Petrochemical Plants. - Furniture (Metal & wooden). - External concrete and masonry - Offshore platforms and marine installations. - Aluminium Window Frames and A/C ventillation covers. - Well prepared steel structure subjected to proper priming and/or undercoating. - Particularly suited as a protective coat over textured systems, i.e., Rolltex, Trowtex and Spatter Finish Paints where minimum yellowing and dirt retention is anticipated.
Product data
FINISH : SEMI-GLOSS COLOUR : White, Black and selected colour range Special colours are available upon request VOLUME SOLIDS : 47% PRODUCT WEIGHT : 1.44 kg/ltr. REC. FILM THICKNESS : Wet : 110 microns per coat (approx. 4.3 mils/coat) Dry : 50 microns per coat THEO. COVERAGE : 9.41 m2/ltr. Practical coverage primarily depends upon nature of surface profile, method of application and site conditions. MIXING RATIO : Base : Curing Agent 8 1 (by volume) POT LIFE : Ambient Temperature 10 °C 25 °C 45 °C 50 °F 77 °F 113 °F No. of Hours 12 hrs. 8 hrs. 4 hrs. FLASH POINT : Base : 23 °C (73 °F) Curing Agent : 23 °C (73 °F) Mixed : 23 °C (73 °F)
Drying times
SUBSTRATE TEMPERATURE TOUCH DRY HARD DRY FULL CURE TIME OVERCOATING INTERVALS MINIMUM MAXIMUM 10 °C (50 °F) 4 hrs. 30 hrs. two weeks 24 hrs. IND. 25 °C (77 °F) 3 hrs. 20 hrs. one week 18 hrs. IND. 40 °C (104 °F) 2 hrs. 16 hrs. 5 days 16 hrs. IND.
Standards and approvals
Supportive information is available upon request to establish an assessment to be acquired as with regards to product's compliance with/to a particular authority's queries / specifications. Please consult with GTC Technical Service Dept.
Surface preparation
1. Surface to be coated/overcoated must be dry, clean and free from contamination. 2. Degrease metal surfaces in accordance with SSPC-SP1 Solvent Cleaning. (Use GTC002 Thinner). 3. Porous surfaces i.e., concrete, masonry ... etc should be sound and free from laitance, powdery and foreign material. (Wire brushing and/or power tool cleaning is normally adequate in accordance with SSPC-SP2 and/or SSPC-SP3 Standards). 4. Non-ferrous surfaces i.e., Aluminium, copper, nickle ... etc. should be degreased and free from contamination. No pre-treatment is required.
Mixing and thinning
Individual components should be separately mixed and then added together according to stated mixing ratio where mixing should be properly done. Thinning with GTC 077 Getathane Thinner should be carried out after mixing base with Curing Agent as per below table:- Application Method Brush/ Roller Conv. Spray Airless Spray Thinning by Vol (% Max.) 10% 20% 5%
Where to use
To be applied in two or three coat system over suitably primed and undercoated surfaces as detailed below:- NO. SUBSTRATE TYPE: RECOMMENDED PRIMER RECOMMENDED INTERMEDIATE COAT RECOMMENDED NO. OF GETATHANE RECOATABLE SEMI-GLOSS FINISH 1 Steel & Ferrous Metals Getoxy Selected Range of Primers Getoxy GEM Mastic or GEH MIO Series Two Coats or as required 2 Galvanized Steel Getoxy Zinc Chromate Epoxy Primer Getoxy GEM Mastic or GEH MIO Series Two Coats or as required 3 Non-Ferrous Metals Not required Not Required Two Coats or as required 4 Concrete & Masonry Getoxy Clear Sealer or Getathane Clear Coating Getathane Recoatable Flat Finish One Coat or as required 5 GTC Textured Finishes Not Required Getathane Recoatable Flat Finish One Coat or as required 6 Marble Getathane Clear Coating Not Required One or Two Coats 7 Wooden Surfaces Getathane Clear Coating or Getoxy Clear Sealer Not Required One Or Two Coats
Important restrictions
Other substrates. Please consult with GTC Technical Service Dept'.
Cleaning tools
For cleaning tools and equipments use GTC 077 Getathane Thinner.
Application conditions
At a temperature ranging 5°C (41°F) to 40°C (104 °F). Relative humidity is below 75%.
Storage and handling
Product must be stored as per local regulations and should be kept in dry well ventilated location far from heat and direct sunlight. Can should be tightly closed after use. Mix well before use. Storage temperature range between 5°C (41°F) to 40°C (104 °F).
Safety precautions
The following notes should be considered when using/applying painting material:- (a) Take precautions to prevent material entering the eyes (goggles should be worn, irrigate the eyes with water when become contaminated and obtain medical care at once). (b) Take precautions to avoid skin contact (gloves should be worn, barrier cream should be used). (c) Ensure that repeated contact of paint with skin is avoided. (d) Provide adequate ventilation. (Face masks must be worn). (e) Keep away from sparks and open flames (for solvent-based materials).
Pack sizes
White : - 3.6 Ltr Tins (Base + Curing Agent) - 18 Ltr Tins (Base + Curing Agent) Colours :- - Volume will vary according to colour.